Return to list

Five-step method to optimize your chiller's cooling performance

2021-05-31

  For chillers used over the long term, cooling performance tends to decline over time. However, chiller users no longer need to worry about this issue—below, we’ll share five effective methods to restore and enhance your chiller’s cooling efficiency.

  1. Regularly inspect the screw-type chiller compressor

  The compressor is the "heart" of the screw chiller unit, and its quality directly affects the stability of the entire system. If the compressor fails and requires repair, the costs can be quite high—especially since screw compressors are highly precise and come with a hefty price tag. Therefore, if you notice any unusual noises or other signs of malfunction in the compressor, it’s crucial to contact the manufacturer of the screw chiller unit and consult with a qualified engineer to diagnose the issue and arrange for proper repairs.

  2. Regularly clean the condenser and evaporator of the screw chiller unit.

  The condenser/evaporator is a critical component of screw chillers and typically requires cleaning every six months. In water-cooled condensers, the cooling water follows an open-loop circulation system, with tap water continuously recycled through a cooling tower. However, over time, this water can accumulate dissolved impurities that harden into scale, depositing on the pipe walls and reducing heat transfer efficiency. Excessively thick scale buildup not only narrows the flow cross-section of the cooling water but also decreases the overall water volume—and worse, it can drive up condensing pressure. Therefore, when the quality of tap water is poor, it’s generally recommended to clean the system at least once a year to remove accumulated scale from the pipes.

  3. Regular Inspection of Safety Valves in Screw Chillers

  The condenser and evaporator of the industrial screw chiller are both pressure vessels. According to regulations, a safety valve must be installed on the high-pressure side of the screw chiller—specifically, on the condenser body itself. This ensures that, in the event of abnormal operating conditions, the safety valve can automatically relieve pressure, preventing potential harm to personnel caused by excessive high pressure.

  4. Regularly replace the lubricating oil in screw chillers

  After prolonged use, the quality of the lubricating oil in screw chillers tends to deteriorate, with increased levels of impurities and moisture. Therefore, it’s important to regularly monitor and inspect the oil condition. If any issues are detected, the oil should be replaced promptly—ideally using the same brand of lubricant originally supplied by the manufacturer.

  5. Regularly replace the screw-type chiller's dryer filter

  The dry filter is a critical component that ensures the proper circulation of refrigerant. Since water and refrigerants are incompatible, the presence of even small amounts of moisture in the system can significantly reduce the operational efficiency of screw-type chillers. Therefore, maintaining a dry system is essential, and the filter element inside the filter-dryer must be replaced regularly.